Puressentiel Sputnik Ultrasonic Humidifier Diffuser 1 piece

Puressentiel Sputnik Ultrasonic Humidifier Diffuser 1 piece

AED 347.00
+ AED 111.00 Air Shipping

  • Includes any applicable VAT and customs duty.
  • Air shipping cost to be recalculated with delivery address at checkout.
  • To be delivered in 6 - 9 * working days.
  • 100% genuine and new product.
  • Credit card / Cash on Delivery
Description
1. Steam outlet
2. Cover
3. Notch in the cover, to be positioned above the two control buttons on the base
4. Water container
5. The maximum filling level must not be exceeded
6 . Air outlet
7. Ultrasonic plate
8. Diffusion button
9. Programmed stop button
10. LED display protection area
Before any handling, make sure that the diffuser is switched off and the plug is pulled.
Attention - Never lift your diffuser by grasping it by the upper part (the cover). Always hold it at its base. Do not remove (or lift) the cover during diffusion. Do not use the device for purposes other than those intended.
1 Place the diffuser on a stable surface and a safe distance from an edge (it could tip). Do not place on or near furniture or moisture-sensitive surfaces.
2 Grip the top of the cover to remove.
3 Fill the container with a sufficient amount of cold water (between 180ml and 200ml). Caution - Do not use hot water as this may damage the diffuser. Do not exceed the maximum level in the container (indicated by an arrow at the base).
4 Add a few drops of essential oil or Puressentiel diffusion mixture: usually 1 drop per 10 ml of water is enough.
5 Replace the cover, making sure to position the notch over the 2 control buttons on the base.
6 Plug the end of the power adapter into the DC jack input on the bottom of the diffuser and close that Connect the power adapter to a power outlet.
7 Empty the container by tilting it to the side where the ultrasonic plate is located (opposite the air outlet) after diffusion has ended.
Operating modes
A. Continuous diffusion / Mode “ON”
Press once on the left button of the LED function display of the diffuser position A.
- The continuous diffusion is activated (consumption of 13 to 17 ml of water per hour).
- The Diffusion (up to 14 hours) automatically stops when the water level becomes insufficient, with the three LEDs flashing simultaneously for 60 seconds to indicate that the container is empty.
B. Intermittent Diffusion
Press after the To activate the ON mode a second time, press the left button on the diffuser LED function display position B.
- The intermittent diffusion is activated: the diffuser runs for 15 seconds and then stops for 15 seconds.
- The diffusion (until to 28 hours) stops automatically when the water level is no longer sufficient, with the three LEDs flashing simultaneously for 60 seconds to indicate that the container is empty.
C. Diffusion with programmed shutdown after 1 hour After you press the ON button Mode activated (left button) and the type of diffusion (continuous or intermittent) selected, press once the right button of the diffuser LED function indicator in position C.
- The diffuser runs for 60 minutes and then turns off automatically.
To exit the diffusion mode with timer, press the right button a second time:
- Diffusion stops automatically when the water level is no longer sufficient, with the three LEDs flashing simultaneously for 60 seconds to indicate that the container is empty.
Stop
Press the left button twice if you have chosen continuous diffusion and once if you have chosen intermittent diffusion: let yourself be guided by the function indicators (see Section “LED function displays”).
LED function displays 10
The various LEDs inform you about the current operating mode:
- Left LED: Continuous diffusion (A)
- Middle LED: Intermittent diffusion ( B)
- Right LED: Diffusion with programmed interruption after 1 hour (C)
- LEDs flashing: container empty (D)
Cleaning and care
For optimal performance of your diffuser and to avoid failure To avoid damage to the device, care instructions must be followed carefully. Failure to follow these instructions may result in damage to the diffuser.
1. Daily Care
Remove the cover. Empty the water tank, taking care not to let the water enter the air outlet. Rinse the inside of the container thoroughly with clean water to remove any residue.
Then dry with a soft cloth. Fill the container with water (as described in the “Instructions for Use”).
2. Weekly Care
Repeat the steps in the “Daily Care” section. Fill the container with a mixture of white vinegar and a little water and let this solution sit for 15 minutes. Then, using a cotton swab, carefully remove any residue from the container and from the ultrasonic plate located at the bottom of the container; be careful not to scratch the plate. Then empty the water-vinegar mixture from the container, rinse it thoroughly with clean water and dry it with a soft cloth.
3. Care instructions
Do not use soap or harsh cleaning agents to clean the diffuser , dishwashing liquid, gasoline, glass cleaner, furniture polish or paint thinner or other products that may give off toxic fumes when evaporated.
- Before diffusing essential oils in the presence of a child under 7 years of age, seek the advice of a health professional (unless , this use is expressly stated on the product). After diffusion has ended, wait 30 minutes before letting the child back into the room.
- Children must not play with the device.
- Do not use essential oils, which are not recommended for use for diffusion. Do not use perfumes or synthetic scents, these can cause irreparable damage to the diffuser. Some essential oils are not recommended for diffusion, ask your pharmacist for advice. Check the instructions for use of each essential oil before using it for diffusion.
- The device should only be used with substances recommended for diffusion.
- Substances not recommended may pose a toxic or fire hazard.
- Cleaning and maintenance to be carried out by the user must not be carried out by a child.
- The device must only be used with the power supply supplied.
- Before connecting the device, make sure that the voltage at the connection location corresponds
matches that of the device. The power cord must never run under a carpet or near a heat source such as a radiator, stove or heater.
- Under no circumstances use the device if the power cord or the socket to which you
If you want to connect the device, it is damaged, the device is not working or if it has been dropped or damaged.
- Unplug the diffuser before filling and cleaning the container.
- Fill cold water into the diffuser provided Water tank.
- Do not point the steam outlet directly at a wall.
- Under no circumstances move or empty the diffuser while it is in use. Turn off and unplug the diffuser before emptying or moving it.
- Empty the container when the device is not in use.
- Never leave water in the container when the device is not is in use. Empty and clean the device before storing it for a long period of time. Clean the device before using it again.
- When the diffuser is in use, its cover must not be removed and it
must not be covered.
- Empty and refill the container every three days. Clean the container before refilling it. Remove any limescale, deposits or films that have formed on the container walls or interior surfaces. Wipe all surfaces mentioned.
- If a malfunction occurs, do not disassemble or attempt to repair the device. This will void the warranty. Only factory technicians are authorized to disassemble or repair the device (see contractual warranty).
- Do not block the air inlet/outlet.
- Never hold the diffuser under running water or immerse it in any liquid.
- Detailed information about Filling, cleaning and descaling can be found in the “Care” section.
- This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capabilities or by people without experience or knowledge, unless they are supervised by a person responsible for their safety or have been previously instructed in the use of the device.
- High humidity can favor the development of microorganisms in the environment.
- Warning: Microorganisms in the water of the Diffuser or the environment in which the device is used or stored can multiply in the water container and become airborne. Failure to change the water every 3 days and clean the container properly can result in serious health risks.
1 piece
Show More
Product Information
  • Brand :
  • Category :
Images
-
Reviews

Be the first to review. Login

Puressentiel Sputnik Ultrasonic Humidifier Diffuser 1 piece

AED 347.00
+ AED 111.00 Air Shipping
  • Includes any applicable VAT and customs duty.
  • Air shipping cost to be recalculated with delivery address at checkout.
  • To be delivered in 6 - 9 * working days.
  • 100% genuine and new product.
  • Credit card / Cash on Delivery
Share on: